Medium Voltage Cable ( 3.6 kV to 30 kV )
Aplikasi
Kabel Kontrol :
Aplikasi normal kabel tersebut adalah kabel yang dapat
langsung di taman di bawah tanah atau dalam saluran atau rak, di lokasi yang
basah dan kering. Posibilitas spesifik berikut dapat disebutkan:
1. Instalasi dalam bangunan ( Vertical Mounting)
1. Instalasi dalam bangunan ( Vertical Mounting)
2. Instalasi dirute dengan perbedaan ketinggian yang besar
3. Instalasi di gardu dan pembangkit listrik
3. Instalasi di gardu dan pembangkit listrik
Tipe dari Medium voltage Cable adalah :
1. N2XSY/NA2XSY
Rate Voltage and construction :
-
Voltage :
3.6/6 – 18/30 kV
-
Standard :
IEC – 502 SPLN 43 – 5
Construction :
-
Conductor :
Copper or Aluminium
-
Conductor Screen :
Semi Conductive Compound
-
Insulation :
XLPE
-
Insulation Screen :
Semi Conductive Compound
-
Metallic Shield :
Copper Tape ( s )
-
Outer Sheath :
PVC 90⁰C grade
-
Single Core
2. N2XSEY / NA2XSEY
Rate Voltage and Construction :
-
Voltage :
6/10 – 12/20kV
-
Standard :
IEC – 502 SPLN 43 – 5
Construction :
-
Conductor :
Copper or aluminium
-
Conductor Screen :
Semi Conductive Compound
-
Insulation :
XLPE
-
Insulator Screen :
Semi Conductive Compound
-
Metallic Shield :
Copper Tape
-
Bedding/Separator :
PVC 90⁰C grade
-
Outher Sheath :
PVC 90⁰C grade
-
3 cores cable XLPE insulation
3. N2XSEBY / NA2XSEBY
Rated Voltage and Construction :
-
Voltage :
3.6/6 – 18/30kV
-
Standard :
IEC – 502 , SPLN 43 – 5
Construction :
-
Conductor :
Copper or Aluminium
-
Conductor Screen :
Semi Conductive Compound
-
Insulation :
XLPE
-
Insulator Screen :
Semi Conductive Compound
-
Metallic Shield :
Copper Tapes
-
Armoured :
Steel tapes
-
Outer Sheath :
PVC 90⁰C grade
-
3 cores cables XLPE insulation – Double Steel Tapes
Armoured PVC Sheathed
4. N2XSEFGby / NA2XSEFGby
Rated Voltage and Construction :
-
Voltage :
3.6/6 – 18/30kV
-
Standard :
IEC – 502 , SPLN 43 – 5
Construction :
-
Conductor :
Copper or Aluminium
-
Conductor Screen :
Semi Conductive Compound
-
Insulation :
XLPE
-
Insulator Screen :
Semi Conductive Compound
-
Metallic Shield :
Copper Tapes
-
Armoured :
Steel flat wire interlocked with steel tape
-
Outer Sheath :
PVC 90⁰C grade
-
3 Cores Cables
5. NFA2XSEY – T
Rated Voltage and Construction
-
Voltage :
3.6/6 – 12/20kV
-
Standard :
IEC – 502 , SPLN 43 – 5
Construction :
-
Conductor :
Aluminium
-
Conductor Screen :
Semi Conductive Compound
-
Insulation :
XLPE
-
Insulator Screen :
Semi Conductive Compound
-
Metallic Shield :
Copper Tapes
-
Outer Sheath :
PVC 90⁰C grade
-
Messenger :
Hard Steel Wire Stranded
-
Three Single – Core Overhead Cables Aluminium Conductor
6. NF2XSEY / NFA2XSEY
Rated Voltage and
Construction :
-
Voltage :
3.6/6 – 12/20kV
-
Standard :
IEC – 502 , SPLN 43 – 5
Construction :
-
Conductor :
Copper or Aluminium
-
Conductor Screen :
Semi Conductive Compound
-
Insulation :
XLPE
-
Insulator Screen :
Semi Conductive Compound
-
Metallic Shield :
Copper Tapes
-
Outer Sheath :
PVC 90⁰C grade
-
Three Single – Core Cables Copper Conductor